{"product_id":"bayoxide-e33-karton-arsenic-removal-media-20kg","title":"Bayoxide E33 Karton Arsenic Removal Media 20kg","description":"\u003cp\u003e\u003cspan style=\"font-size: 10pt; font-family: Arial; font-style: normal;\"\u003eBayoxide E33 Arsenic Removal Media – 20kg\u003cbr\u003e\u003cbr\u003eBayoxide E33 is a specialist water treatment media designed for the effective removal of arsenic from water. The dry crystalline media is based on iron hydroxide technology and has been specifically formulated to provide a high arsenic removal capacity while remaining strong, reliable and easy to handle.\u003cbr\u003e\u003cbr\u003eBayoxide was developed through work between Severn Trent Water and Bayer and is Regulation 31 approved for use in both municipal and private water supplies. The media provides long operating cycles and low operating costs, making it suitable for domestic, commercial and larger water treatment applications where arsenic contamination is present.\u003cbr\u003e\u003cbr\u003eDuring operation, water passes down through the Bayoxide media bed. Arsenic is captured and retained within the media while treated water passes through the system. Periodic backwashing removes accumulated sediment without removing the captured arsenic. Once the media reaches its arsenic holding capacity, it can be replaced with fresh media. Depending on the arsenic concentration and local water conditions, replacement may typically be required every couple of years.\u003cbr\u003e\u003cbr\u003eBayoxide systems can also be combined with other water treatment processes where necessary. Sand filtration can be installed where turbidity is high, iron and manganese filtration can be used where these contaminants exceed the recommended limits, and pH correction can be incorporated where the incoming water has a low pH.\u003cbr\u003e\u003cbr\u003eThe exhausted media is described as non-hazardous and can generally be disposed of to landfill, although local disposal regulations and conditions must always be checked.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 10pt; font-family: Arial; font-style: normal;\"\u003e- Specialist media for arsenic removal\u003cbr\u003e- High arsenic removal capacity\u003cbr\u003e- Dry crystalline iron hydroxide-based media\u003cbr\u003e- Strong, reliable and easy to handle\u003cbr\u003e- Regulation 31 approved for municipal and private water use\u003cbr\u003e- Long operating cycles\u003cbr\u003e- Low operating costs\u003cbr\u003e- Automatic backwashing can be used to remove accumulated sediment\u003cbr\u003e- Can be combined with other water treatment media and filtration systems\u003cbr\u003e- Exhausted media is generally considered non-hazardous, subject to local disposal requirements\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOperating Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 10pt; font-family: Arial; font-style: normal;\"\u003e- Service flow rate: 15–18 m\/h\u003cbr\u003e- Backwash flow rate: 25 m\/h\u003cbr\u003e- Recommended backwash frequency: Every 14–28 days\u003cbr\u003e- Recommended operating pressure: 20–120 psi\u003cbr\u003e- Water temperature range: 2–38°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRecommended Raw Water Conditions\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eFor effective operation, the incoming water should meet the following conditions:\u003cbr\u003e\u003cbr\u003e- Iron: \u0026lt;200 µg\/L\u003cbr\u003e- Manganese: \u0026lt;50 µg\/L\u003cbr\u003e- Suspended solids: \u0026lt;10 mg\/L\u003cbr\u003e- pH: 6.5–8.5\u003cbr\u003e- SiO₂: \u0026lt;40 mg\/L\u003cbr\u003e- PO₄: \u0026lt;200 µg\/L\u003cbr\u003e\u003cbr\u003eWater outside these parameters should be appropriately pre-treated before passing through the Bayoxide media. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSystem Design Considerations\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eCorrect system sizing should take both normal water consumption and peak flow requirements into account. The PDF gives an average consumption figure of approximately 160 litres per person per day and notes that a family of four typically uses around 700 litres per day, with peak demand potentially reaching 300 litres within one hour.\u003cbr\u003e\u003cbr\u003eWhere the arsenic concentration exceeds 50 µg\/L, the document states that two treatment systems may be required in series in a lead\/lag configuration. The first system removes the majority of the contamination, while the second acts as a polishing stage to remove the remaining arsenic.\u003c\/span\u003e\u003c\/p\u003e","brand":"Water Filter Men","offers":[{"title":"Default Title","offer_id":58510885617995,"sku":"MED-BAYOXIDE-20KG","price":695.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0487\/5904\/6303\/files\/BayoxideE33KartonArsenicRemovalMedia20kgpromo.jpg?v=1789658481","url":"https:\/\/thewaterfiltermen.ie\/products\/bayoxide-e33-karton-arsenic-removal-media-20kg","provider":"Water Filter Men","version":"1.0","type":"link"}